Champ VMVL LED Hazardous Area Light Fixtures

The Crouse-Hinds series Champ VMVL LED is our flagship LED fixture for Class I and Class II hazardous area mid bay and high bay downlighting.  It is available in nine models ranging from 3,000 lumens to 25,000 lumens.  This offers a lighting solution for areas with mounting heights from 8’ all the way up to 60’.

Champ VMVL LED light fixtures are engineered to provide maintenance-free operation, while delivering long life and high lumen performance.  The Type 4X fixture provides up to 127 lumens per watt, and custom Type I, III and V optics maximize light distribution and intensity.

Champ VMVL LEDs are certified for use in NEC, CEC and IEC hazardous locations, providing a single solution for applications around the world.  These light fixtures are ideal for indoor and outdoor general area lighting in oil and gas refineries, drilling rigs, petrochemical plants, food and beverage facilities, and other industrial applications where flammable gases, vapors, dusts, fibers or flyings are present.

The VMVL LED is also available with an integral battery back-up system for emergency lighting applications.  In the event of power loss or power interruption, our Champ LEDs with with battery back-up provide 90 minutes of emergency lighting.

 

Reliability
60,000 hours at 55°C ambient
Performance
Custom optics for ideal light distribution
Safety
Globally certified for haz areas

Certifications and compliances

NEC®, CEC and IEC:

  • Class I, Division 2, Groups A, B, C, D
  • Class II, Division 1, Groups E, F, G
  • Class III
  • Class I, Zn.2 AEx ec IIC, ZN.21 AEx tb IIIC
  • Class I, Zn.2 Ex ec IIC, ZN.21 Ex tb IIIC
  • Ex ec IIC T* Gc
  • Ex tb IIIC T*° C Db
  • II 3 G Ex ec IIC T* Gc
  • II 2 D Ex tb IIIC T*°C Db
  • Simultaneous presence
  • Marine and Wet locations, Type 4X, IP66

UL® standards:

  • UL 844; UL 1598; UL 1598A; UL8750; UL 50E
  • UL 60079-0; UL 60079-7; UL 60079-31

CSA® standards:

  • CSA C22.2 No. 137; CSA C22.2 No. 94.2; CSA C22.2 No. 250.0; CSA C22.2 No. 250.13
  • CSA C22.2 No. 60079-0; CSA C22.2 No. 60079-7; CSA C22.2 No. 60079-31

IEC and EN standards:

  • IEC/EN 60079-0; IEC/EN 60079-7; IEC/EN 60079-31

Luminaire markings:

  • IECEx UL 19.0039X
  • DEMKO 19 ATEX 2118X
  • DEMKO 19 ATEX 2119X
spacer

NEC, CEC and IEC

  • Class I, Division 2, Groups A, B, C, D
  • Class I, Zn. 2 AEx ec mb IIC Gc, ZN. 21 AEx tb IIIC Db
  • Class I, Zn. 2 Ex ec mb IIC Gc, ZN. 21 Ex tb IIIC Db
  • Class II, Division 1, Groups E, F, G
  • Class III
  • Ex ec mb IIC T*
  • Ex tb IIIC T*ºC Db
  • II 3 G Ex ec mb IIC T* Gc
  • II 2 D Ex tb IIIC T*ºC Db
  • Simultaneous Presence
  • Marine and Wet locations, Type 4X, IP66

UL standards

  • UL844; UL1598 Luminaires; UL1598A Marine

CSA standard

  • CSA C22.2 No. 137

IEC/ATEX standards†:

  • IEC 60079-0:2011, 6th Edition / EN 60079-0:2012
  • IEC 60079-7:2010, 5.1 Edition / EN 60079-7:2015
  • IEC 60079-31:2008, 2nd Edition / EN 60079-31:2014
  • IEC 60529:2001 / EN 60529:2001
  • IEC 60598-1:2008 / EN 60598-1:2008
  • IEC 60598-2:2008 / EN 60598-2:2008
  • IEC 60079-18:2017, 4.1 Edition / EN 60079-18:2015 + A1:2017

† IEC/ATEX certifications applicable for voltage ranges: 100-277VAC, 127-250 VDC.

Luminaire markings:

  • IECEx UL 13.0052X
  • DEMKO 13 ATEX 1305741X
  • DEMKO 13 ATEX 1475031X

 

spacer

NEC, CEC and IEC

  • Class I, Division 2, Groups A, B, C, D
  • Class I, Zn. 2 AEx ec mb IIC Gc, ZN. 21 AEx tb IIIC Db
  • Class I, Zn. 2 Ex ec mb IIC Gc, ZN. 21 Ex tb IIIC Db
  • Class II, Division 1, Groups E, F, G
  • Class III
  • Zone 21 tb (UNV1 model only)
  • Ex ec mb IIC T*
  • Ex tb IIIC T*ºC Db
  • II 3 G Ex ec mb IIC T* Gc
  • II 2 D Ex tb IIIC T*ºC Db
  • Simultaneous Presence
  • Wet locations, Type 4X, IP66

UL standards

  • UL844; UL1598 Luminaires; UL1598A Marine; UL8750; UL50; UL50E

CSA standard

  • cUL Listed to CSA Standard CSA C22.2 No. 137

IEC/ATEX standards†:

  • IEC 60079-0:2011, 6th Edition / EN 60079-0:2012
  • IEC 60079-7:2010, 5.1 Edition / EN 60079-7:2015
  • IEC 60079-31:2008, 2nd Edition / EN 60079-31:2014
  • IEC 60529:2001 / EN 60529:2001
  • IEC 60598-1:2008 / EN 60598-1:2008
  • IEC 60598-2:2008 / EN 60598-2:2008
  • IEC 60079-18:2017, 4.1 Edition /  EN 60079-18:2015 + A1:2017

† IEC/ATEX certifications applicable for voltage ranges: 100-240VAC, 127-250 VDC.

Luminaire markings:

  • IECEx UL 14.0031X
  • DEMKO 14 ATEX 1324722X
  • DEMKO 14 ATEX 2274231X
spacer

Design features - Engineered for safe and reliable performance in extreme environments

Montage of Champ LED M2 models
  • Globally certified:  For use in classified, hazardous areas around the world
  • Nine models:  From 3,000 lumens to 25,000 lumens for areas with mounting heights of 8-60 feet
  • Rated life:  60,000 hours at 55ºC ambient.  Economic life ranges from 7 to 20 years.
  • Operating ambient:  -40°C to 65°C (VMVL-3 to VMVL-13 models); -40°C to 55°C (VMVL-17 to VMVL-25 models)
  • Environmental rating:  Type 4X, IP66
  • Corrosion resistance:  Corrosion resistant aluminum housing with Corro-free™ epoxy power coating
  • Vibration resistance:  Tested in accordance with Section 33 of UL 844
  • Impact resistance:  Tested in accordance with Section 68 of UL 844
  • Surge protection:  6kV standard (10kV available upon request)
Champ VMVL LED M2 3L-7L light fixture - tophat callout
Champ VMVL LED M2 3L-7L light fixture - internal callouts

Mounting module & driver housing

A.  Contractor-friendly universal top hats

  • Seven mounting module styles help ensure that the fixtures are installed in the correct location to properly light your facility
  • All Crouse-Hinds series Champ LED luminaires utilize the same mounting modules as our legacy HID products, simplifying installation and significantly reducing costs in retrofit projects
  • Mounting adapters and kits available for quick connection to other manufacturers' modules

B.  Fully serviceable drivers

  • Drivers are isolated from the primary heat source (LED engine) to maximize economic life
  • Dimmable, 0-10V

C.  Lever lock connectors and terminal blocks

  • Plug and play wiring simplifies and speeds installations
  • Accepts 10-20 AWG wire
Champ VMVL LED M2 3L-7L light fixture - engine callout
Champ VMVL LED M2 3L-7L light fixture - optics callout

LED Engine and heat sink

A.  Die cast aluminum heat sink

  • Housing fins ensure proper air flow & facilitates dust-shedding for effective heat dissipation and thermal management of LED engine

B. Integral carrying handle

  • Simplifies transportation and installation at the job site

C.  Custom optics and colors

  • Type I, III, and V optics direct light where you need it, helping eliminate gaps and dark spots, and potentially reducing the number of light fixtures required in your application
  • 5000K (cool white) standard.  Available in 4000K (neutral white), 3000K (warm white), and 2200K (deep warm DarkSky ready) color options.  Green and Amber LEDs also available for wildlife conservation applications.

D.  Custom lenses

  • Glass or polycarbonate lens with clear or diffused finishes available to meet customer requirements or preferences

Reduce costs by optimizing your lighting system and eliminating over-usage

Our Champ light fixtures are now available with Brightlayer Lighting control and insight software, delivering full lighting control at your fingertips — improving safety, maximizing energy savings and minimizing maintenance costs.

Standard materials

  • Lamp housing and adapter – die cast aluminum with Corro-free epoxy powder coat
  • Lens – heat- and impact-resistant glass (clear or diffused) or polycarbonate
  • Gaskets – silicone
  • External hardware – stainless steel
  • Factory sealed, no external seals required
  • Contains no mercury or other hazardous substances

Videos

    How to eliminate dark areas while maximizing savings

    Using lighting layouts provided by the Crouse-Hinds design team, Benchmark Electrical Solutions was able to reduce the proposed fixture count from the competitor by roughly 30%.

    Drawings and design support

    Specifications

    Highlight differences
    Show only differences
    Hide blank features
    Download Links